Radial treatment of right cerebral aneurysm

Preoperative data

The patient is a female with a 2-year history of hypertension. A cerebral aneurysm was discovered during a physical examination. MRA and CTA revealed an aneurysm in the A1 segment of the right anterior cerebral artery, hard plaques in the walls of the bilateral internal carotid arteries’ siphons, and mild stenosis of the lumen. The left vertebral artery was slender, its terminal branch continuing as the posterior inferior cerebellar artery; the right vertebral artery had hard plaques at its origin and mild stenosis of the lumen; cerebral arteriosclerosis was also present.

arcanmedical
arcanmedical

Surgical plan

Planned treatment for an A1 segment aneurysm via right radial artery using a Pipeline flow-guided mesh stent.

6F radial artery sheath

Rist 6F 105cm distal radial artery access catheter

Pigtail-type angiography catheter

Phenom 27 microcatheter

Pipeline Shield flow-guided mesh stent

0.014-inch guidewire

0.010-inch guidewire

Surgical procedure

Establishment of a radial artery access:

A 6F Rist, angiography catheter, and guidewire are assembled into a coaxial system externally;

A 6F radial artery sheath is inserted, and the Rist 6F is coaxially guided to the vicinity of the brachiocephalic trunk;

The opening of the right common carotid artery is identified by angiography. Using the guidance of the angiography catheter tip, the guidewire is superselectively inserted into the right common carotid artery and then superselectively into the right internal carotid artery;

The angiography catheter is fixed, and the Rist 6F is advanced to the C2 segment of the internal carotid artery. The angiography catheter and guidewire are then withdrawn.

Dense mesh stent treatment pathway established:

A 0.014’’ guidewire guides the Phenom 27 to the terminal bifurcation of the internal carotid artery, passing over the A1 aneurysm neck opening;

A Rist 6F guidewire is advanced to the C4 segment of the internal carotid artery;

A 0.014’’ guidewire is advanced to the A3 segment, with a 0.010’’ guidewire running parallel within the Phenom 27 to reduce the step effect at the microcatheter tip, reaching the aneurysm neck opening to the A2 segment, completing the treatment pathway establishment;

Pipeline Shield stent treatment procedure:

1. Deliver the Pipeline Shield stent, ensuring its main body crosses the aneurysm neck opening and is positioned between the A1 level segment and the A2 ascending segment, with a planned pull-back release;

2. Advance the Rist 6F to the C4 segment for locking, maintaining constant system tension and providing sufficient stable support;

3. While withdrawing the Phenom 27, simultaneously advance the Pipeline Shield flow-directing mesh stent, observing full distal opening, then withdraw until complete release. Angiography confirms good stent opening;

4. Use the microguidewire and Phenom 27 to massage and proximal push the stent, ensuring full apposition to the stent wall;

Postoperative images

Immediate postoperative angiography showed that the Pipeline Shield adhered well to the wall, and contrast agent retention was evident.

Summary and Review

Treatment of intracranial aneurysms via the radial route is becoming increasingly sophisticated. Using a small-diameter transradial catheter significantly reduces the risk of postoperative radial artery occlusion, offering convenient operation and a more comfortable experience for patients. The Pipeline Shield flow-directing mesh stent, made of cobalt-chromium-nickel alloy, offers superior wall apposition and therapeutic benefits. This advantage requires sufficiently reliable system support during placement and release, a requirement even more stringent in the transradial angulation approach. The Rist 6F provides excellent support and stability during Pipeline Shield procedures, allowing for flexible tension adjustments to achieve good stent apposition. Its placement at C4 provides independent access for most anterior circulation lesions, eliminating the need for additional intermediate catheters.