Coronary ORCAS technology

Contents

What is the ORCAS technology for coronary arteries? Why is it used? How is it performed?

In the complex field of interventional cardiology, calcified coronary artery lesions have always been a serious challenge for physicians. In particular, lesions at the aortic-coronary ostium, due to their unique anatomical location and high degree of calcification, often lead to incomplete dilation or geographic loss after stent implantation, thereby increasing the risk of restenosis and target lesion revascularization.

Traditionally, intravascular ultrasound (IVUS), as an important tool for optimizing interventional treatments, has been primarily used for preoperative assessment and postoperative validation, but rarely for real-time dynamic guidance during procedures. However, a recent case study published in *Clin Case Rep* proposes an innovative technique called “ORCAS”—Ostial Rodin Cut Angioplasty and Stenting, which involves sequential cutting balloon angioplasty and stent implantation at the ostium under real-time IVUS guidance. This technique deeply integrates real-time IVUS imaging with the sequential expansion of the cutting balloon, allowing for precise and controllable operation at every step. This article delves into the essence of ORCAS, exploring its clinical value and potential challenges.

IVUS

I. What is ORCAS technology?

ORCAS technology is not an isolated device or a single step, but a systematic interventional strategy. Its core lies in “sequential lesion preparation and stent implantation guided by real-time IVUS.” The abbreviation ORCAS stands for “Ostial Rodin Cut Angioplasty and Stenting,” which literally translates to “Rodin Cut Angioplasty and Stenting at the aortic ostium.” (The word Rodin is used to commemorate the great sculptor Auguste Rodin [1840–1917]). “Rodin-CUT” refers to the use of a cutting balloon for multiple high-pressure dilations to mechanically modify calcified plaques; while “Ostial” emphasizes the technique’s focus on the high-risk site of aortic-coronary ostium lesions. The unique aspect of this entire process is that IVUS is not merely used for preoperative planning or postoperative verification, but rather throughout the entire process from lesion preparation to stent implantation, achieving true real-time dynamic navigation.https://eurointervention.pcronline.com/article/clinical-use-of-intracoronary-imaging-part2-acute-coronary-syndromes-ambiguous-coronary-angiography-findings-and-guiding-interventional-decision-making-an-expert-consensus-document-of-the-european-association-of-percutaneous-cardiovascular-interventions?utm_source=chatgpt.com

Rodin-CUT Technology Diagram

Specifically, ORCAS technology consists of three key components:

First, based on initial IVUS assessment, parameters such as the degree of calcification and minimum luminal area (MLA) of the lesion are precisely quantified, providing baseline data for subsequent treatment.

Second, the application of the Rodin-CUT technique involves sequential high-pressure dilation using a cutting balloon, with IVUS pullback imaging immediately after each dilation to assess plaque modification effects until ideal luminal gain is achieved.

Third, IVUS-guided stent placement dynamically adjusts the stent position by placing the IVUS probe directly near the coronary artery ostium, ensuring complete coverage of the ostium while minimizing stent protrusion into the aorta.

This closed-loop operation of assessment-modification-verification transforms the interventional procedure from a blind operation relying on angiography into a visualized surgery based on intravascular imaging.

In this case, the ORCAS technique was applied to a right coronary artery ostium lesion in an 82-year-old female patient. The lesion was severely calcified, with initial IVUS showing a calcification arc of 270° and an MLA of only 2.7 mm², below the ischemic threshold of the right coronary artery. Through the ORCAS procedure, the final MLA was increased to 6.39 mm², the minimum stent area (MSA) after stent implantation reached 18.96 mm², and the aortic protrusion was less than 1 mm. This quantitative result fully demonstrates the precision of the ORCAS technology.

II. Why is ORCAS technology needed?

Why is a technology like ORCAS needed? The main reason is the unique nature of lesions at the aortic and coronary ostia and the limitations of traditional methods. Due to their challenging anatomical location, aortic and coronary ostia lesions often involve highly elastic recoil and calcified rings. Traditional balloon dilation is often ineffective, and stent implantation can easily lead to incomplete dilation or geographic loss—that is, the stent fails to completely cover the lesion area, resulting in marginal restenosis.

More problematic is the inherent limitation of relying solely on coronary angiography for guidance: it offers a “two-dimensional view.” Angiography cannot clearly show the distribution of calcifications in the vessel wall, the nature of plaques, or accurately define the anatomical boundaries of the ostia. Therefore, physicians often rely on experience to determine stent placement, inevitably leading to errors.

While IVUS can compensate for the shortcomings of angiography by providing sectional images, in traditional applications, IVUS is mostly used for preoperative assessment of lesion severity or postoperative verification of stent dilation effectiveness. The imaging process and the treatment procedure are often disconnected. This means that physicians cannot obtain real-time intravascular imaging feedback during balloon dilation or stent implantation and can only rely on pre-set plans or postoperative adjustments. This “operate first, verify later” approach is particularly passive in complex lesions. Once geographical loss or incomplete dilation occurs, remedial measures are often less effective.

The great innovation of ORCAS technology lies in upgrading IVUS from a static tool to dynamic navigation. Its advantages are reflected in three aspects: First, real-time performance. During the Rodin-CUT phase, IVUS imaging is performed immediately after each balloon dilation, allowing physicians to visually observe whether calcified plaques have cracked or the lumen has widened, thus deciding whether additional dilation or strategy adjustments are needed. The “plaque fragmentation” phenomenon described in the case, where the calcified ring is mechanically broken into small fragments, was dynamically captured by real-time IVUS. This feedback ensures that lesion preparation is just right. Second, precision. In the stent positioning phase, the IVUS probe is placed directly within the coronary sinus, aligned with the ostium, forming a bullseye view, reducing the positioning error of the proximal stent edge to the millimeter level. Through real-time visual adjustments, complete coverage of the ostium and stent protrusion into the aorta of less than 1 mm are ultimately achieved, which was almost unimaginable in the era of angiography alone. Finally, integration. ORCAS seamlessly integrates image guidance with treatment procedures, reducing intraoperative guesswork, radiation exposure, and operation time—in this case, the surgery took only 48 minutes with a radiation dose of 654 mGy, far below the average level for similar complex surgeries.

Furthermore, ORCAS technology embodies the concept of personalized medicine. Unlike standard procedures that require a one-off approach, it allows doctors to flexibly adjust strategies based on real-time intravascular imaging. For example, in this case, five balloon dilation procedures were required to confirm that the MLA target was met, demonstrating dynamic adaptation to the lesion response. This image-guided precision medicine undoubtedly represents the future direction of interventional cardiology.

III. ORCAS Technical Details and Procedural Explanation

How to implement ORCAS technology in practice? This case study breaks down the process into five steps, each deeply integrated with real-time IVUS guidance.

Step 1: Preoperative Assessment and Pathway Establishment

The patient was an elderly woman with a history of PCI who presented with recurrent chest pain. Angiography revealed severe stenosis and calcification at the ostium of the right coronary artery (Figure 1). The procedure was performed via the radial artery approach using a 7Fr guiding catheter and RailTracking (a sheathless technique for long dilators). Initial IVUS assessment confirmed concentric calcification, with an MLA of 2.7 mm², and the old stent did not cover the ostium area. The key to this stage was that IVUS not only quantified the lesion but also identified the treatment target—plaque modification of the calcified ring.

Angiography

((A) Angiography – The right coronary artery (blue arrow) has a severely calcified and narrowed ostial lesion (black arrow). (B) IVUS shows a ring of dense calcification at the lesion site.)

Step Two: Rodin-CUT Lesion Preparation – Sequential Dilation and Real-Time Validation

Lesion preparation is the core of the ORCAS technique. A 3.5/15 mm cutting balloon was used for high-pressure dilation (18 atm) (Translator’s note: off-label use). Uniquely, after each dilation, IVUS observation was performed immediately to assess the degree of plaque modification, rather than immediately proceeding to the next step. In this case, after five consecutive dilations, IVUS showed that the calcified arc gradually fragmented (from 270° to fragments at 100° and 90°), while the MLA gradually increased from 2.7 mm² to 6.39 mm² (Figure 3). This “dilation-imaging-decision” cycle ensured adequate but not excessive lesion preparation. Notably, IVUS played a real-time monitoring role here, visually displaying the plaque fragmentation pattern, laying the foundation for stent implantation.

Cutting balloon

((A) IVUS images after multiple balloon dilation with cutting showed calcification and plaque rupture (white arrows), presenting as a state of plaque destruction. (B) IVUS images after pretreatment showed a significant increase in MLA, confirming the satisfactory effect of lesion pretreatment using the RODIN-CUT technique.)      product link:  https://www.arcanmedical.com/product/balloon-dilatation-catheter/

Step 3: IVUS-guided stent positioning – overcoming the challenge of opening alignment

The biggest challenge in stent implantation at the ostium is geographic loss. Because the right coronary artery ostium is located high up, simple angiography can easily lead to the stent being inserted too deeply or protruding into the aorta. The ORCAS technology offers a clever solution (Figure 2): the second guidewire, originally used for IVUS pullback, is repositioned within the right coronary sinus, allowing the IVUS probe to be directly aligned with the ostium level, creating a real-time navigation view. Stent placement is then adjusted under IVUS image guidance (Figure 4): the initial attempt resulted in the stent being too deep (geographic loss), the second attempt resulted in excessive protrusion, and finally, precise positioning under IVUS dynamic guidance achieved perfect alignment. This stage highlights the positioning function of IVUS, transforming the traditional angiography-dependent “estimate, approximate, roughly” approach into image-based “precision guidance.”

RODIN-CUT

(The RODIN-CUT method was used for cutting balloon dilation, an effective pretreatment of calcified ostial lesions. The image below shows real-time IVUS-guided stent placement, where the IVUS catheter is positioned at the right coronary artery ostium to ensure accurate alignment and avoid geographic loss.)

Angiography of the ostium of the right coronary artery

((A) Angiography of the right coronary artery ostium, with the stent (gray triangle) positioned under the guidance of an IVUS probe (blue asterisk), and the IVUS guidewire within the right coronary sinus. (B) IVUS shows the stent balloon edge is too deep (light blue arrow), resulting in incomplete ostium coverage (yellow arrow) (geographical loss). (C) IVUS shows the balloon edge protruding excessively into the aorta (light blue arrow), posing a risk of stent protrusion. (D) IVUS confirms optimal final stent positioning (light blue arrow), precise ostium coverage (yellow arrow), and minimal protrusion into the aorta.)

Step 4: Stent Implantation and Final Verification

After stent implantation, IVUS immediately confirmed the dilation effect, showing that the stent balloon was fully inflated, with an MSA of 18.96 mm² (Figure 5), and the stent protruding into the aorta by only 0.8 mm (Figure 6). These quantitative data not only verified the success of the procedure but also provided assurance for long-term prognosis. The final image showed that the stent had a hyperechoic structure with internal reflection, indicating that the metallic stent adhered well to the vessel wall.

IVUS

((A) IVUS image: Visualization of stent balloon dilation (indicated by yellow arrow). The right coronary artery ostium is marked by a light blue arrow. (B) IVUS image: Fully dilated stent after deployment with a large MSA.)

operating room

(IVUS measurement of stent protrusion into the aorta. (A) Proximal segment of the right coronary artery, located at the ostium, marked at frame 612 (20.4 mm from the start of retraction). (Light blue arrow). (B) The last visible protruding stent strut in the aorta, located at frame 637 (21.2 mm from the start), indicating a stent protrusion of only 0.8 mm. (Light blue arrow).)

Step 5: Postoperative Follow-up

The patient was asymptomatic during the 6-month follow-up, demonstrating the short-term effectiveness of this technology.

Through these five steps, the ORCAS technology transforms interventional surgery into a real-time, dynamically guided process. Its essence lies not in the innovation of instrument usage, but in the deep integration of imaging and treatment.

After thoughts

The ORCAS technology case study is both inspiring and thought-provoking. It’s inspiring because it represents a leap in interventional cardiology from an experience-based art to a precise science. Real-time IVUS guidance provides physicians with a real-time navigation system, making the treatment of complex lesions controllable and measurable. Especially for senior interventional cardiologists, this technology not only improves surgical success rates but also reduces anxiety caused by intraoperative uncertainties—after all, operating within millimeters of blood vessels, any error can be costly.

However, behind the brilliance of this technology often lie real-world challenges. The “instrument friction” issue mentioned in the article is a pain point that physicians may deeply understand. ORCAS technology requires the guiding catheter to simultaneously accommodate the IVUS probe and treatment instruments (such as a cutting balloon or stent). This is manageable with the 7Fr system, but if the lesion is more complex or the instruments are larger, it may cause friction within the catheter, affecting the smoothness of the operation. In this case, the “ping-pong technique” may need to be used, that is, quickly exchanging guidewires or instruments to avoid mutual interference. This technique requires operators to possess exceptional coordination skills, akin to balancing in acrobatics; even the slightest misstep can lead to delays or vascular damage. Furthermore, frequent movement of the IVUS probe may increase the risk of vascular injury. How to balance precision and safety is a crucial issue that needs careful consideration in clinical implementation.

A deeper question arises: can ORCAS technology be widely adopted? While real-time IVUS guidance is excellent, it demands significant medical resources, including equipment costs, physician training, and time investment. In most primary hospitals, angiography may still be the dominant method. Therefore, it may be more suitable as a reserve technology. Regardless, the value of ORCAS lies in pointing the way: future interventional treatment will inevitably move towards an era of image-guided personalization. We look forward to further technological optimizations, such as thinner IVUS catheters and AI-assisted image analysis, to further lower the operational threshold.

In short, ORCAS technology is not only a methodological innovation but also an evolution of a treatment philosophy. For interventional physicians dedicated to conquering calcified lesions, this case reminds us that the integration of imaging and treatment is always worth exploring in the pursuit of technological advancement.

John Doe
John Doe@username
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
John Doe
John Doe@username
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
John Doe
John Doe@username
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.