Clinical value and boundary exploration of drug-coated balloons(III)

IV. DCB operation essentials: lesion preparation and outcome evaluation

Successful DCB surgery=sufficient lesion preparation+precise DCB delivery+rigorous outcome evaluation;
Step 1 Disease preparation – the cornerstone of successful DCB;
Objective: To achieve a residual stenosis of<30%, an unrestricted blood flow dissection, and achieve sufficient lumen gain.
Tool: Conventional use of non compliant balloons for pre dilation. For elastic retraction or fibrotic lesions, cutting balloons or scoring balloons are preferred. For severe calcification, intracoronary rotational atherectomy or shockwave balloon should be considered.
Imaging guidance: Intravascular ultrasound can accurately evaluate plaque properties, vessel size, and stent dilation, which is of great value in optimizing DCB efficacy.

Step 2: Result evaluation – “Determine whether the threshold for DCB can be used
Effectiveness criteria (must be met): residual diameter stenosis<30%, no significant retraction, and satisfactory acute lumen gain achieved.
Safety criteria (must be none): no persistent chest pain, electrocardiographic ischemic changes, no restricted blood flow dissection (TIMI flow<grade 3), no persistent contrast agent retention, no progressive luminal stenosis, blood flow reserve score/instantaneous no waveform ratio>0.90 (if available).
If the result is not satisfactory, the “remedial stent implantation” should be discontinued.

Step 3:
DCB delivery and postoperative management DCB selection: diameter 1:1, length covering the pre-treatment section and exceeding 2mm at both ends.
Expansion parameter: Named pressure, lasting for 60-90 seconds to ensure drug delivery.
Dual therapy course: For stable De Novo lesions, experts recommend at least 4 weeks. For patients with extremely high bleeding risk, shortening to 2 weeks or even monoclonal antibody treatment can be considered.

Summary and outlook:

This authoritative review from JAMA Cardiology clearly depicts the evolutionary roadmap of DCB technology in the field of coronary intervention: from the savior of ISR, to the optimization of small vessel lesions, and then to the core tool for implementing the “stent burden reduction” strategy in complex lesions.

Future direction:

The advantages and disadvantages of sirolimus DCB versus paclitaxel DCB require more head to head research to define. The ultimate localization of DCB and contemporary DES in de novo lesions remains to be determined by the final results of large RCTs such as SELUTION DeNovo.
The safety of shorter DAPT schemes needs further prospective research verification.

For interventional cardiologists, mastering DCB technology is no longer just a ‘icing on the cake’, but a necessary skill for dealing with complex coronary artery diseases and achieving individualized and precise treatment for patients. At the same time, we cannot mythologize drug balloons. They are just one of our optional tools, and maximizing the benefits for patient health is fundamental. We hope that everyone can work together to encourage them.